Skill 6Procedural Skill

IV Fluid Infusion

Assessor

PGY2+, Nurse, NP

Due

Week 7

Requirement

Mandatory

Details

Prime line and apply to patient safely

What Assessors Look For

Correct fluid selection
Aseptic technique for line setup
Complete priming (no air bubbles)
Safe connection to patient
Rate calculation and setting

Key Points to Demonstrate

1Check prescription: fluid type, volume, rate, additives
2Check fluid: correct bag, in-date, no particles, intact seal
3Prime line: spike bag, hang high, open roller clamp, prime until no bubbles
4Connect: clean hub with chlorhexidine, connect, check flow
5Rate: mL/hr = total volume ÷ hours; drops/min = volume × drop factor ÷ minutes

Tips for Success

  • 💡Always check the prescription with another person if adding potassium
  • 💡Tap bubbles to the top and flush through
  • 💡Label the line with time started

Study Resources